Part Number Hot Search : 
2M80V2 N25F80 KK071 C1815 M5218A 74479153 1702I R3010
Product Description
Full Text Search
 

To Download AM1601-7R Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 M Series
50 Watt DC-DC Converters
Wide input voltage from 8...372 V DC 1, 2 or 3 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage
LGA
* Rugged electrical and mechanical design * Outputs individually controlled with excellent dynamic properties * Operating ambient temperature range -40...71C
Selection chart
Output 1 Output 2 Uo nom Io nom Uo nom Io nom [V DC] [A] [V DC] [A] 5.1 8 12 4 15 3.4 24 2 48 1 12 2 12 2 15 1.7 15 1.7 5.1 5 12 0.7 5.1 5 15 0.6 Output 1 Output 2 Uo nom Io nom Uo nom Io nom [V DC] [A] [V DC] [A] 5.1 8 12 4 15 3.4 24 2 48 1 12 2 12 2 15 1.7 15 1.7 5.1 5 12 0.7 5.1 5 15 0.6 Output 3 Uo nom Io nom [V DC] [A] 12 0.7 15 0.6 Type Input voltage 8...35 V DC AM 1001-7R AM 1301-7R AM 1501-7R AM 1601-7R AM 1901-7R AM 2320-7 AM 2540-7 AM 3020-7 AM 3040-7 Type Type Input voltage Input voltage 14...70 V DC 20...100 V DC BM 1001-7R FM 1001-7R BM 1301-7R FM 1301-7R BM 1501-7R FM 1501-7R BM 1601-7R FM 1601-7R BM 1901-7R FM 1901-7R BM 2320-7 FM 2320-7 BM 2540-7 FM 2540-7 BM 3020-7 FM 3020-7 BM 3040-7 FM 3040-7 Options
-9, P, D, V, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, V, A, H, F -9, P, D, V, A, H, F Options
Output 3 Type Type Type Uo nom Io nom Input voltage Input voltage Input voltage [V DC] [A] 28...140 V DC 44...220 V DC 88...372 V DC CM 1001-7R DM 1001-7R LM 1001-7R CM 1301-7R DM 1301-7R LM 1301-7R CM 1501-7R DM 1501-7R LM 1501-7R CM 1601-7R DM 1601-7R LM 1601-7R CM 1901-7R DM 1901-7R LM 1901-7R CM 2320-7 DM 2320-7 LM 2320-7 CM 2540-7 DM 2540-7 LM 2540-7 12 0.7 CM 3020-7 DM 3020-7 LM 3020-7 15 0.6 CM 3040-7 DM 3040-7 LM 3040-7
-9, E, P, D, V, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, V, A, H, F -9, E, P, D, V, A, H, F
CM, DM and LM types available as CMZ, DMZ and LMZ class II equipment
2/12.2000
www.power-one.com
1
Cassette Style
Input
Input voltage Inrush current limitation 6 wide-input ranges (1:5) CM, DM, LM by thermistor
M Series
refer to selection chart
Output
Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation main output Current limitation aux. output(s) Operation in parallel Hold-up time
Ui nom, Io nom up to 83% Ui nom, Io nom 0.6% Uo nom IEC/EN 61204, total typ. 50 mVpp Ui min...Ui max, Io nom, each output regulated typ. 0.3% Uo nom Ui nom, 0...Io nom, each output regulated typ. 0.15% Uo nom not required 0A rectangular U/I characteristic typ. 110% Io nom rectangular U/I characteristic typ. 120% Io nom by current limitation, only main outputs Ui nom, Io nom, LM typ. 100 ms Ui nom, Io nom, A/B/C/D/FM with ext. diode in input line up to 7 ms
Protection
Input reverse polarity Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature built-in fuse typ. 80% Ui min typ. 110% Ui max varistor or suppressor diode no-load, overload and short circuit proof suppressor diode in each output switch-off with auto restart
typ. 150% Uo nom TC typ. 100C
Control
Output voltage adjustment Inhibit Status indication single output types TTL input, output(s) disabled if open circuit LEDs: OK, inhibit, overload 0...110% Uo nom
Safety
Approvals Class of equipment Protection degree Electric strength test voltage EN 60950, UL 1950, CSA C22.2 No. 950 AM, BM, CM, DM, FM, LM CMZ, DMZ, LMZ units without options class I, I/case class I, I/O class II, CMZ/DMZ/LMZ, I/O and I/case O/case O/O class I class II IP 40 2 kV AC 4 kV AC 4 kV AC 1 kV AC 0.2 kV AC
www.power-one.com
2
M Series
EMC
Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions
50 Watt DC-DC Converters
IEC/EN 61000-4-2, level 4 (8/15 kV) IEC/EN 61000-4-3, level x (20 V/m) IEC/EN 61000-4-4, input, level 3/4 (2/4 kV) IEC/EN 61000-4-5, input, level 3/4 (2/4 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022, conducted criterion B criterion A/B criterion A/B criterion A criterion B class B
Environmental
Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump Random vibration MTBF
Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40C IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-27, 6 ms IEC/EN 60068-2-29, 6 ms IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217E, GB, 40C, single output types
-25...71C -25...95C -40...100C 56 days 0.35 mm/5 gn 100 gn 40 gn 4.9 gn rms 320'000 h
Options
Extended temperature range -40...71C, ambient, operating Electronic inrush current limitation Output voltage adjustment 95...105% Uo nom, excludes feature R and vice versa Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D Test sockets for check of output voltage Enhanced electric strength test 2 kV AC Fuse not user accessible -9 E P D0...D9 V0, V2, V3 A H F
Pin allocation
Pin 2 5 8 11 14 17 14 17 20 23 26 29 32 Electrical determination Inhibit control input Safe data or ACFAIL Output voltage (positive) Output voltage (negative) Control input + Control input - Output voltage (positive) Output voltage (negative) Output voltage (positive) Output voltage (negative) Protective earth DC input voltage DC input voltage AM...LM 1000 i D or V Vo1+ Vo1- R G CMZ...LMZ 1000 i D or V Vo1+ Vo1- R G AM...LM 2000 i D or V CMZ...LMZ 2000 i D or V AM...LM 3000 i D or V Vo3+ Vo3- CMZ...LMZ 3000 i D or V Vo3+ Vo3-
Vo1+ Vo1- Vi+ Vi-
Vo1+ Vo1- Vi+ Vi-
Vo2+ Vo2- Vo1+ Vo1- Vi+ Vi-
Vo2+ Vo2- Vo1+ Vo1- Vi+ Vi-
Vo2+ Vo2- Vo1+ Vo1- Vi+ Vi-
Vo2+ Vo2- Vo1+ Vo1- Vi+ Vi-
www.power-one.com
3
Cassette Style
Mechanical data
Tolerances 0.3 mm (0.012") unless otherwise indicated.
2 5 8 11 14 17 20 23 26 29 32
S09012
M Series
European Projection
20 (0.79")
2TE
6TE
103 M 3; depth = 4 mm (chassis mount)
168.5 (6.63")
173.7 (6.84")
127 (5")
22 (0.87")
Measuring point for case temperature TC
68
111.2 (3U) (4.38")
38.7 (1.52")
OK Inhibit i Potentiometer (option D) or potentiometer (option V)
IoL Test sockets (option A) Potentiometer(s) (option P)
Accessories
Front panels 19" (Schroff/Intermas) Mating H11 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting
www.power-one.com
4


▲Up To Search▲   

 
Price & Availability of AM1601-7R

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X